gGastro® Hardware Compatibility
Compatible Printers
gGastro® utilizes network printers (black and white or color laser) that are compatible with Microsoft Windows. Many, if not all, printers recognized by Windows (with or without a print server) should work with gGastro.
Label Printer
- Dymo LabelWriter 350, 400, 450, 450 Turbo Label Printers, and 550
Compatible Scanners
gGastro scanners require a TWAIN driver (typical for most contemporary scanners). Multi-function machines that copy, scan, fax and print can be problematic and are not recommended.
Card Scanners (gPM™ Only)
Inuvio EcoScan i4d (DocketPORT 488)
Inuvio OCR software is compatible to work with Twain-compliant scanners. Scanner quality has a direct correlation to the accuracy and read rate that is provided by the hardware, so those with higher ratings are suggested.
Compatible Video Capture Cards for Procedure Room Workstations
Inogeni SDI2USB3 (HD)
Osprey Video 915 (HD)
Osprey Video 925 (HD)
Osprey VB-USL USB Video Bridge Capture Device (HD)
Video Capture Card and Processor Compatibility Matrix
Osprey Video 915 (HD)** | Osprey Video 925 (HD)** | Osprey VB-USL USB Video Bridge (HD) | Inogeni SDI2USB3 (HD) | |
Pentax Processor | ||||
Control Cable | #KWRM6327Gxxx | #KWRM6327Gxxx | #KWRM6327Gxxx | #KWRM6327Gxxx |
Video Cable | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) |
Fujinon Processor | ||||
Control Cable | #KWRM10005Gxxx | #KWRM10005Gxxx | #KWRM10005Gxxx | #KWRM10005Gxxx |
Video Cable | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) |
Olympus Processor (CV-180, CV-190) | ||||
Control Cable | #KWRM4748Gxxx | #KWRM4748Gxxx | #KWRM4748Gxxx | #KWRM4748Gxxx |
Video Cable | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) |
Adapter Cable | Olympus 55565A-1 (4”) | Olympus 55565A-1 (4”) | Olympus 55565A-1 (4”) | Olympus 55565A-1 (4”) |
Olympus Processor (CV-1500) | ||||
Control Cable | #KWRM6327Gxxx | #KWRM6327Gxxx | #KWRM6327Gxxx | #KWRM6327Gxxx |
Video Cable | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) | BNC to BNC Cable (RG59, 75Ohm) |
** For EPK-i models – This model sends HD signal out of either the DVI or VGA ports only. In addition to what is listed above, the customer will need a DVI to SDI or VGA to SDI converter.
xxx = cable length
Please contact your MMGI Project Manager or gSupport for any configurations not listed on this chart.
Pentax Processor | |
Osprey Video 915 (HD)** | Control Cable: #KWRM6327Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Osprey Video 925 (HD)** | Control Cable: #KWRM6327Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Osprey VB-USL USB Video Bridge (HD) | Control Cable: #KWRM6327Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Inogeni SDI2USB3 (HD) | Control Cable: #KWRM6327Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Fujinon Processor | |
Osprey Video 915 (HD)** | Control Cable: #KWRM10005Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Osprey Video 925 (HD)** | Control Cable: #KWRM10005Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Osprey VB-USL USB Video Bridge (HD) | Control Cable: #KWRM10005Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Inogeni SDI2USB3 (HD) | Control Cable: #KWRM10005Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Olympus Processor (CV-180, CV-190) | |
Osprey Video 915 (HD)** | Control Cable: #KWRM4748Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) Adapter Cable: Olympus 55565A-1 (4”) |
Osprey Video 925 (HD)** | Control Cable: #KWRM4748Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) Adapter Cable: Olympus 55565A-1 (4”) |
Osprey VB-USL USB Video Bridge (HD) | Control Cable: #KWRM4748Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) Adapter Cable: Olympus 55565A-1 (4”) |
Inogeni SDI2USB3 (HD) | Control Cable: #KWRM4748Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) Adapter Cable: Olympus 55565A-1 (4”) |
Olympus Processor (CV-1500) | |
Osprey Video 915 (HD)** | Control Cable: #KWRM6327Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Osprey Video 925 (HD)** | Control Cable: #KWRM6327Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Osprey VB-USL USB Video Bridge (HD) | Control Cable: #KWRM6327Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
Inogeni SDI2USB3 (HD) | Control Cable: #KWRM6327Gxxx Video Cable: BNC to BNC Cable (RG59, 75Ohm) |
** For EPK-i models – This model sends HD signal out of either the DVI or VGA ports only. In addition to what is listed above, the customer will need a DVI to SDI or VGA to SDI converter.
xxx = cable length
Please contact your MMGI Project Manager or gSupport for any configurations not listed on this chart.
To purchase customized cables from Control Cable:
Primary Contact:
Sharon
Toll Free: 800-296-4411
Direct Line: 443-690-3028
Email: [email protected]
Secondary Contact:
Susan Stewart
Email: [email protected]
*Please include the email address of both contacts on all email purchases.
Please note: Production and delivery time for custom cables may vary. Control Cable will give an approximate delivery date at the time of checkout
Disconnected Video Capture Workstation Application
This application is needed when gGastro is unavailable, or the network connection is down. Please refer to the Install Disconnected Video Capture for gGastro® QRG on Communities for more information.
Disconnected Video Capture Workstation Download
Compatible Vital Signs Monitors
Criticare nGenuity (8100E) Vital Sign Monitor rev (1.2)
Criticare nGenuity (8100E) Vital Sign Monitor rev (2.7)
FUKUDA DS-8410 & DS-8100
GE B125
Mindray Accutorr 7 (System Software Version 3.5)
Mindray DataScope Accutorr V
Mindray DataScope Passport 2
Mindray DataScope Passport 8
Mindray DataScope Passport 12
Mindray DataScope Passport V
Mindray DataScope Trio
Mindray DataScope Spectrum
Mindray cPM8/cPM12
Mindray ePM10/ePM12
Mindray VS9
WelchAllyn Spot Vital Signs LXi (Model: 45NTO)
WelchAllyn VSM 6000 Series (Software Version: 1.70.03)
Vital signs monitors (with the exception of the WelchAllyn models) must have an available serial port (DB-9) in order to interface with gGastro. Please check with distributor prior to purchasing monitors.
The vital signs monitors can transmit data to the gMonitor workstation via a Bluetooth wireless connection or a wired (cable) connection depending on the individual client setup, the distance between areas, and a number of other factors unique to the client’s configuration.
Vital Signs gMonitor Workstation Service Download
gKiosk™ and gGastro® Mobile Hardware Requirements
Modernizing Medicine Gastroenterology supports the latest device operating system version for gKiosk and the two most recent device operating system versions for gGastro Mobile.
Each application works with the device listed below:
gKiosk Device: iPad
gGastro Mobile Devices:
iPhone: iPhone 5S and newer
Android: Phones that support Android Version 8.0 and higher
Technical Documents
The latest version of the Technical Requirements document can be found on ModMed® Communities or by clicking here.
gGastro® Desktop Agent
The Desktop Client is required on any gGastro® / gPM™ / ModMed® ASC workstation that will use any Ancillary Devices, such as Image Capture, Scanning, Importing, Printing, Card Scanning, Label printing, and EPCS (Electronic Prescribing of Controlled Substances).
Please refer to the Desktop Client Release Notes to identify which versions of gGastro® / gPM™ / ModMed® ASC are supported.
Video Streaming
Beginning with gGastro version 5.0, video streaming recording is only compatible with Chrome browser.